Inverter IF Module Product Introduction
Ce Module IF onduleur offre d'excellentes performances typiques, with power ranging from 150W to 500W to meet medium-power inversion needs. It supports a wide range of DC input voltages, y compris 9-18, 18-36, 36-72, 70-140, 198-242, 200-400, et 400-800 V CC, ensuring compatibility with diverse power supply systems. Pour la tension de sortie, it offers multiple AC options such as 6, 12, 26, 36, 115, 200, 220, and 380VAC, adapting to different load requirements.
Users can choose the output frequency freely from 25Hz to 2600Hz and select between single-phase or three-phase output based on application scenarios. The module provides optional pure sine wave or square wave output, catering to loads with varying waveform demands. Its package size is selected according to power and voltage (see the selection table for details), and it supports 1-channel or 2-channel output configurations for flexible use.
With efficiency up to 85%, the module minimizes energy loss during inversion. It offers optional wire outlet methods for easy installation, and supports TTL high-low level control. Users can adjust the output voltage, and program control is available as an option. It also has comprehensive protection functions to prevent damage from abnormal conditions. En plus, its electrical parameters and dimensions can be customized. Ce Module IF onduleur combines versatility and reliability, suitable for various inversion applications.
Expert en solutions d'alimentation
DC-AC Inverter Module Power Supply
ZY Series 150-500W ZY Series 150-500W
- Low distortion, fast transient response
- Conforme à la norme RoHS, UL1950, Règles de sécurité IEC950
- High isolation voltage, court-circuit, surcharge, protection interne contre la surchauffe avec récupération automatique
- TTL high/low level control, adjustable output voltage, single-phase or three-phase output optional
- Small volume, light weight, easy installation, wiring method optional
- Six-sided metal shielding, internal overall potting, good outer casing shielding and vibration resistance performance
- Input voltage, output voltage, pouvoir, fréquence, size, etc.. can be customized as required
- Largement utilisé dans l'armée, medical, communication, transportation and automation industries
Caractéristique générale
| Article de test | Conditions d'essai | Minimum | Valeur nominale | Maximum | Unité |
|---|---|---|---|---|---|
| Tension d'isolement | IN-OUT; 60S, Courant de fuite <5mA | 500 | – | – | VCC |
| Tension d'isolement | IN-FG; 60S, Courant de fuite <5mA | 500 | – | – | VCC |
| Tension d'isolement | OUT-FG | 500 | – | – | VCC |
| Résistance d'isolation | IN-OUT; IN-FG; OUT-FG | 100 | – | – | MΩ |
| Surtension | 10~55Hz | 5 | – | – | G |
| Temps moyen entre les pannes (MTBF) | MIL-HDBK-217F2 | – | 5×10⁵ | – | heures |
| Over-Current Protection/Short-Circuit Protection/Over-Heat Protection | Plage de tension d'entrée complète | – | Auto-récupération | – | – |
| Méthode de refroidissement | – | – | Conductive Heat Dissipation (additional heat dissipation by pasting equipment body is optional)/Natural Heat Dissipation | – | – |
Caractéristique d'entrée
| Tension d'entrée | Valeur nominale | Plage de tension | Valeur nominale | Plage de tension |
|---|---|---|---|---|
| 12VCC | 10-18VCC | 220VCC | 198-242VCC | |
| 24VCC | 20-32VCC | 300VCC | 200-400VCC | |
| 48VCC | 40-60VCC | 600VCC | 400-650VCC | |
| 110VCC | 90-120VCC | – | – | |
| – | – | Other input voltage ranges please consult customer service | – |
Caractéristique de sortie
| Article de test | Conditions d'essai | Minimum | Valeur nominale | Maximum | Unité |
|---|---|---|---|---|---|
| Précision de la tension | Rated resistive load, nominal input voltage | – | – | ±2 | % |
| Régulation de tension | Rated resistive load, low-end ~ high-end input voltage | – | – | ±1 | % |
| Régulation de charge | 10% ~ 100% charge résistive, nominal input voltage | – | – | ±2 | % |
| Harmonic Distortion | 20 MHz bandwidth, 20% of rated load | – | – | 3 | % |
| Output Waveform | 20 MHz bandwidth | – | Pure Sine Wave, Square Wave Optional | – | – |
| Point limite actuel | Vimin≤Vis≤Vimax | 110 | – | 150 | % |
| Réponse transitoire | 25% load change | – | – | 400 | µs |
| Fréquence de fonctionnement | Vimin≤Vis≤Vimax | – | 25, 50, 75, 400, 1000, 1200, 2000, 2600… (Facultatif) | – | Hz |
| Three-Phase Phase Difference | Output is three-phase | – | 120±1 | – | ° |
| Adjustable Output Voltage | – | – | External potentiometer, RS232/422 remote control adjustment, synchronous adjustment optional when output is three-phase voltage | – | – |
Caractéristique de l'environnement
| Article de test | Conditions d'essai | Minimum | Valeur nominale | Maximum | Unité |
|---|---|---|---|---|---|
| Operating Ambient Temperature | Qualité industrielle/qualité militaire | -25/-40 | – | +55/+55 | °C |
| Température maximale du boîtier | Qualité industrielle/qualité militaire | – | – | +85 | °C |
| Température de stockage | Qualité industrielle/qualité militaire | -40/-55 | – | +85/+85 | °C |
| Humidité relative | Pas de condensation | 10 | – | 90 | RH (%) |
| Coefficient de température | – | – | ±0,02 | – | %/°C |