The Программируемый тестер соответствия требованиям безопасности «пять в одном» 1009018 (Model VICTOR 9350) integrates AC withstand, DC withstand, insulation resistance, grounding resistance, and leakage current testing. It adopts DDS digital synthesis technology to generate precise, stable, pure, and low-distortion sine waves, ensuring high testing accuracy.
This tester features adjustable voltage rise and fall times to meet diverse test object requirements, and supports dual-frequency comprehensive testing (50Гц, 60Гц). It offers a bilingual (Chinese/English) operation interface, catering to different user needs. With a memory capacity to store 140 test files (each with up to 20 test steps), it comes standard with PLC, RS232C, RS485, and USB interfaces. A 7-inch TFT (800*480) display clearly presents setup and test parameters.
In terms of specifications, AC withstand test covers 0.050kV~5.000kV (±(1%+0.2% full scale), 1V resolution), DC withstand test ranges 0.050kV~6.000kV, insulation test supports 0.050kV~5.000kV (0.2M~10GΩ range), grounding resistance test has a voltage range of 3.0-32.0A, and leakage current test (with optional isolation transformer) spans 30.0V~300.0V. It also includes an MD simulated human body network with 8 standard networks.
Suitable for components, household appliances, insulation materials, electric tools, and new energy vehicles, this tester is ideal for high-voltage testing and automated test systems. Its 卧式 (horizontal) дизайн, arc detection (1mA-20mA), and multiple communication interfaces make it a versatile tool for electronics and electrical industries.
| AC Withstand Test | Диапазон напряжения | 0.050kV ~ 5.000kV | |
| Voltage Accuracy | ±(1% + 0.2% full scale) | ||
| Разрешение | 1В | ||
| Max Output Power | 100VA (5.000кВ/20мА) | ||
| Max Rated Current | 20мА | ||
| Lower Current Range | 0 ~ 50mA, 0 = no lower limit judgment | ||
| Output Waveform | Синусоидальная волна | ||
| Output Waveform Distortion | ≤5% (no-load or pure resistive load) | ||
| Output Signal Type | DDS Linear Power Amplifier | ||
| DC Withstand Test | Диапазон напряжения | 0.050kV ~ 6.000kV | |
| Voltage Accuracy | ±(1% + 0.2% full scale) | ||
| Разрешение | 1В | ||
| Max Output Power | 60Вт (6000кВ/10мА) | ||
| Max Rated Current | 0 ~ 10mA | ||
| Insulation Test | Output Voltage Setting | 0.050kV ~ 5.000kV, Разрешение: 1V/step | |
| Resistance Upper Limit Setting | (0.2M ~ 10G)Ой | ||
| Resistance Lower Limit Setting | (0.1M ~ 10G)Ой | ||
| Voltage Rise Time | 0.1S ~ 999.9S, OFF = voltage rise time off | ||
| Test Time | 0.3S ~ 999.9S, OFF = continuous test | ||
| Voltage Fall Time | 0.1S ~ 999.9S, OFF = voltage fall time off | ||
| Grounding Resistance | Ohmmeter | ≥500V: 0.1MΩ-1.0GΩ ±5%; 1.0G-50.0GΩ ±10%; 50.0GΩ-100.0GΩ ±15% <500В: 0.20MΩ-1.0GΩ ±10%; 1.0GΩ-10.0GΩ |
|
| Диапазон напряжения | (3.0-32.0)А | ||
| Current Accuracy | ±(1% reading + 0.2А) | ||
| Разрешение | 0.1А | ||
| Resistance Upper Limit Setting | Up to 600m | ||
| Resistance Lower Limit Setting | 0 ~ resistance upper limit | ||
| Output Waveform | Синусоидальная волна | ||
| Output Waveform Distortion | ≤3% (no-load or pure resistive load) | ||
| Output Signal Type | Linear Power Amplifier Drive Output | ||
| Current Rise Time | 0.1S ~ 999.9S, OFF = voltage rise time off | ||
| Ток утечки (Optional Isolation Transformer) | Диапазон напряжения | 30.0V ~ 300.0V | |
| Voltage Accuracy | ±1% reading + 2В | ||
| Разрешение | 0.1В | ||
| Max Output Power | 500VA (220В), 300VA (110В) | ||
| Current Upper Limit Setting | 0.1uA ~ 20.0mA | ||
| Current Lower Limit Setting | 0.0uA ~ current upper limit | ||
| MD Simulated Human Body Network | 8 Standard Networks: MD-A(GB/T12113-2003, GB4793.1-2007), MD-B/B1 (GB/T12113-2003, GB4793.1-2007, GB4706.-2005, GB4943.1-2011, GB8898-2011), MD-C (GB/T12113-2003, GB7000.-2015), MD-D(GB4793.1-2007), MD-E(GB9706.1-2007), MD-F (GB7000.-2015), MD-G (GB4943.1-2011, GB4793.1-2007) | ||
| Model Type | Horizontal | ||
| Isolation Transformer | Optional Accessory | ||
| Arc Detection | 1mA-20mA | ||
| Output Frequency | AC 50Hz, 60Гц, GR 5Hz/60Hz | ||
| Input Characteristics | 230V ±10% 50Hz/60Hz | ||
| Test Alarm | Buzzer, LCD Display, FAIL Indicator | ||
| Screen Size | 7-inch TFT LCD | ||
| Communication Interfaces | HANDLER, RS232, RS485, USBDRV (Computer Interface), USBHOST (USB Disk Interface) | ||
| Memory | 16M flash, each file can store 50 test steps | ||