Inverter IF Module Product Introduction
This Inverter IF Module delivers excellent typical performance, with power ranging from 150W to 500W to meet medium-power inversion needs. It supports a wide range of DC input voltages, including 9-18, 18-36, 36-72, 70-140, 198-242, 200-400, and 400-800VDC, ensuring compatibility with diverse power supply systems. For output voltage, it offers multiple AC options such as 6, 12, 26, 36, 115, 200, 220, and 380VAC, adapting to different load requirements.
Users can choose the output frequency freely from 25Hz to 2600Hz and select between single-phase or three-phase output based on application scenarios. The module provides optional pure sine wave or square wave output, catering to loads with varying waveform demands. Its package size is selected according to power and voltage (see the selection table for details), and it supports 1-channel or 2-channel output configurations for flexible use.
With efficiency up to 85%, the module minimizes energy loss during inversion. It offers optional wire outlet methods for easy installation, and supports TTL high-low level control. Users can adjust the output voltage, and program control is available as an option. It also has comprehensive protection functions to prevent damage from abnormal conditions. Additionally, its electrical parameters and dimensions can be customized. This Inverter IF Module combines versatility and reliability, suitable for various inversion applications.
Power Solution Expert
DC-AC Inverter Module Power Supply
ZY Series 150-500W ZY Series 150-500W
- Low distortion, fast transient response
 - Compliant with RoHS standard, UL1950, IEC950 safety regulations
 - High isolation voltage, short-circuit, over-load, internal over-heat protection with self-recovery
 - TTL high/low level control, adjustable output voltage, single-phase or three-phase output optional
 - Small volume, light weight, easy installation, wiring method optional
 - Six-sided metal shielding, internal overall potting, good outer casing shielding and vibration resistance performance
 - Input voltage, output voltage, power, frequency, size, etc. can be customized as required
 - Widely used in military, medical, communication, transportation and automation industries
 
General Characteristic
| Test Item | Test Condition | Minimum | Rated Value | Maximum | Unit | 
|---|---|---|---|---|---|
| Isolation Voltage | IN-OUT; 60S, Leakage Current <5mA | 500 | – | – | VDC | 
| Isolation Voltage | IN-FG; 60S, Leakage Current <5mA | 500 | – | – | VDC | 
| Isolation Voltage | OUT-FG | 500 | – | – | VDC | 
| Insulation Resistance | IN-OUT; IN-FG; OUT-FG | 100 | – | – | MΩ | 
| Surge | 10~55Hz | 5 | – | – | G | 
| Mean Time Between Failures (MTBF) | MIL-HDBK-217F2 | – | 5×10⁵ | – | hrs | 
| Over-Current Protection/Short-Circuit Protection/Over-Heat Protection | Full Input Voltage Range | – | Self-Recovery | – | – | 
| Cooling Method | – | – | Conductive Heat Dissipation (additional heat dissipation by pasting equipment body is optional)/Natural Heat Dissipation | – | – | 
Input Characteristic
| Input Voltage | Nominal Value | Voltage Range | Nominal Value | Voltage Range | 
|---|---|---|---|---|
| 12VDC | 10-18VDC | 220VDC | 198-242VDC | |
| 24VDC | 20-32VDC | 300VDC | 200-400VDC | |
| 48VDC | 40-60VDC | 600VDC | 400-650VDC | |
| 110VDC | 90-120VDC | – | – | |
| – | – | Other input voltage ranges please consult customer service | – | 
Output Characteristic
| Test Item | Test Condition | Minimum | Rated Value | Maximum | Unit | 
|---|---|---|---|---|---|
| Voltage Accuracy | Rated resistive load, nominal input voltage | – | – | ±2 | % | 
| Voltage Regulation | Rated resistive load, low-end ~ high-end input voltage | – | – | ±1 | % | 
| Load Regulation | 10% ~ 100% resistive load, nominal input voltage | – | – | ±2 | % | 
| Harmonic Distortion | 20 MHz bandwidth, 20% of rated load | – | – | 3 | % | 
| Output Waveform | 20 MHz bandwidth | – | Pure Sine Wave, Square Wave Optional | – | – | 
| Current Limit Point | Vimin≤Vis≤Vimax | 110 | – | 150 | % | 
| Transient Response | 25% load change | – | – | 400 | μs | 
| Operating Frequency | Vimin≤Vis≤Vimax | – | 25, 50, 75, 400, 1000, 1200, 2000, 2600… (Optional) | – | Hz | 
| Three-Phase Phase Difference | Output is three-phase | – | 120±1 | – | ° | 
| Adjustable Output Voltage | – | – | External potentiometer, RS232/422 remote control adjustment, synchronous adjustment optional when output is three-phase voltage | – | – | 
Environment Characteristic
| Test Item | Test Condition | Minimum | Rated Value | Maximum | Unit | 
|---|---|---|---|---|---|
| Operating Ambient Temperature | Industrial Grade/Military Grade | -25/-40 | – | +55/+55 | °C | 
| Maximum Case Temperature | Industrial Grade/Military Grade | – | – | +85 | °C | 
| Storage Temperature | Industrial Grade/Military Grade | -40/-55 | – | +85/+85 | °C | 
| Relative Humidity | No Condensation | 10 | – | 90 | RH (%) | 
| Temperature Coefficient | – | – | ±0.02 | – | %/°C | 